You use this section of a process data sheet to calculate liquid density at operating and base conditions in accordance with the API 2540 standard for a selected product.

Select one of the following option buttons and type the values in the appropriate fields. Note that you must enter a reference temperature value to perform the calculation.

Density at Reference Temperature

Select this option button, type the value in the data field, and select the unit of measure from the drop-down list.

Specific Gravity at Reference Temperature

Select this option button and type the value in the data field.

API settings for min/norm/max

Select this option button and type the minimum, normal, and maximum values in the data fields provided.

Reference Temperature

Type the value and select the appropriate temperature unit of measure. Remember that you must enter a reference temperature to perform the calculation.

Default

Retrieves the default reference temperature from the database.

Calculate Density