This topic summarizes the behavior of the pipe parameters under the GENERAL section of the Line Process Data window. There are parameters that you set directly, and others that you set from the Pipe Data Library dialog.

For all pipe standard options — ANSI, DIN, ASME DN, and Other — you can edit the Pipe material and Pipe spec parameters directly.

The following table summarizes the behavior of the software and availability of parameters for editing according to the pipe standard you select.

Pipe Standard

Parameters Set from Pipe Data Library

Editable Parameters

ANSI

Line size, Line schedule, Line internal diameter, Wall thickness

ASME DN

Line size, Line schedule, Line internal diameter, Wall thickness

DIN

Line size, Nominal pressure, Line internal diameter

Wall thickness

Other

Line size and its unit of measure, Line internal diameter, Wall thickness

  • If you change your Pipe standard selection from any different value to ANSI, DIN, or ASME DN, the Pipe Data Library dialog opens.

  • For the pipe standards ANSI, DIN, or ASME DN, to open the Pipe Data Library dialog without changing the pipe standard, select Actions > Pipe Data.