Configure Smart Instrumentation to Use Minor Revisions - Intergraph Smart Instrumentation - Help

Intergraph Smart Instrumentation Help

Language
English
Product
Intergraph Smart Instrumentation
Search by Category
Help
Smart Instrumentation Version
13.1

When adding revisions to Smart Instrumentation publishable reports, the software can be configured to support major and minor revisions that are defined in SmartPlant Foundation.

  1. Select File > Preferences.

  2. On the Preferences dialog, under Instrument Index, select Custom.

  3. Under Custom features for the Instrument Index module, do the following:

    1. Under Parameter, type major.

    2. Under Value for the parameter type rev_udf_c01.

    3. Under Parameter, type minor.

    4. Under Value for the parameter type rev_udf_c02.