  1. Start the Administration module and log on as Domain Administrator.

  2. With the Domain Administration window open, click Add-Ins > Import System Interfaces.

  3. Under Source database, locate the database file in one of the following ways:

    • In the File name and path box, type the path and filename of the database file In_ctlog.DDTI.

    • Click Browse to navigate to In_ctlog.DDTI.

  4. Click Connect to connect to the source database file.

     If you get a message stating that the connection has failed, make sure you typed in the correct path and filename of the database file (see step 3 of this procedure).

  5. Under the Select link group section, select one or more of the link groups to import.

  6. Locate the source path of all the links in the imported group in one of the following ways:

    • In the Source file path data field, type the source path.

    • Click Browse to navigate to the required source path.

  7. Clear the Import only source codes check box if it was selected.

  8. If you are importing the PDS/SmartPlant P&ID link, select or clear the Import typical instruments check box as required.

  9. Click Import to add the selected link group to the database.