Set the preferences to view the tag and item lists in the generated hook-up drawing. For details, see Enhanced Reports > Hook-Ups > View (Preferences).
-
In Smart Instrumentation, from the Domain Explorer, create a new hook-up item.
-
Right-click the hook-up item and select Properties.
-
On the Properties dialog, in the Drawing block file name and path data field, type the name and path of the required SmartSketch block and select OK.
-
Set the drawing generation method for this hook-up item to Enhanced Report. For details, see Apply a Drawing Generation Method to Hook-Ups.
-
Generate the hook-up drawing. For details, see Generate Enhanced Hook-Up Drawings.
The Enhanced Report utility recognizes only tag and hook-up item macros within a SmartSketch block.