This dialog enables you to create a new generic junction box or to edit the properties of an existing junction box that you select in the Domain Explorer or Reference Explorer.

Headers on this dialog box are user-defined and panel manufacturer-specific. The ones shown here are the default headers. If you select a manufacturer, the field headers change accordingly to the settings in the Custom Field Headers dialog box (including child items). To view the field headers, in the Wiring Module window, click Tables > Panel > Manufacturers. To change the field headers, click Headers on the Panel Manufacturer dialog box.

Pane

Allows you to type a new junction box name or edit the displayed one.

Apply naming convention

Allows you to name the new panel automatically according to the naming conventions that are set for this type of panel in the Administration module. For more information, see Smart Instrumentation Administration Help, Domain Administration > Naming Conventions.

Type

Allows you to select a junction box type.

Manufacturer

Allows you to select a junction box manufacturer.

Model

Allows you to select a junction box model.

Dimensions

Allows you to type the junction box dimensions.

Area classification

Allows you to select an appropriate junction box area classification. For example, General purpose, Encapsulated type N, Weatherproof, and so forth.

Location

Allows you to select a location of the junction box. For example, Equipment Room, Control Room, Wall-mounted, Console, and so forth. This field is not available in the Reference Explorer.

Mounting

Allows you to type the kind of mounting required for the junction box. You can leave this field blank if there is no mounting.

Backplane

Allows you to enter the type of the junction box backplane or backplane availability if applicable.

Requires power supply

Not available for junction boxes.

Set as intrinsically safe

Sets the junction box as intrinsically safe so that it complies with intrinsic safety certification for hazardous zones.