In Smart Instrumentation, save the spec page as a .psr file and then open the .psr file in InfoMaker. For details, see Open a Form Page in InfoMaker.
-
On the menu bar, select Insert > Control > Line.
-
On the General tab of the Properties dialog, do the following:
-
Under Name, type l_coordinator.
-
Clear the Visible check box.
-
Make sure that the icon to the right of Visible is displayed as . If the icon is displayed as , select it, and in the dialog that opens, delete the contents of the Expression pane, and then select OK.
-
-
On the Position tab, type the following settings:
X1: 0
Y1: 0
X2: 0
Y2: Type a value equal to or greater than the highest Y2 value on the form.
-
On the menu bar, select File > Save.
-
Import the page back into Smart Instrumentation.
-
Regenerate the spec page and specification, and save the specification again in Excel format.