This procedure enables you to correct discrepancies that can occur on a specific single-section spec page, and to influence the display of various tables and table columns in the Table Column List pop-up window in the Page Editor. When you implement this procedure, Smart Instrumentation the data fields included in the current page according to their current table column definitions in the database.

You can only use this procedure to regenerate a single-section page. If you need to regenerate a composite page, you must regenerate specific sections in the Section Editor.

  1. Open a spec page in the Page Editor.

  2. On the menu bar, select Actions > Regenerate Page.

  3. On the Regenerate Page dialog, under Select tables and views, select a check box for each table or view from which you want to display additional columns in the Table Column List pop-up window.

    Some tables, such as Component and Flow, do not appear in the list. These tables contain mandatory fields and are also regenerated. The fields will appear in the Table Column List window when you open Edit > Column List.

  4. Under Show Columns, select Show for each required table or view.

  5. Under Select columns, do one of the following:

    • Select the Select all check box to select all the columns in the table.

    • Hold down the CTRL key and select or clear specific columns.

  6. Select OK.