Smart Instrumentation calculates the line fluid velocity according to the line internal diameter and volumetric fluid flow at flow conditions.

If you enter fluid flow as mass or volumetric flow at standard / normal / base conditions, Smart Instrumentation will calculate volumetric flow at flow conditions first (using density values) and then the line fluid velocity.

For flowmeters, fluid velocity at operating conditions is calculated automatically according to fluid flow and line internal diameter. If the mass flow value has been entered, density is required for fluid velocity calculation.