On the Windows Start menu, point to the PD Shell program group and select PD Shell.
-
In the Plant Design System Environment window, in the list box, select the PDS project to which you want to import dimensional data for piping, and select Reference Data Manager.
-
Select Piping Job Specification Manager.
-
Select Instrument Data.
-
Under Instrument Data, do the following:
-
In the Node Name box, type the computer name for the <Smart Instrumentation home folder>\DDP\Output folder.
After you type data in a PDS text box, remember to press Enter before continuing.
-
In the File Path box, type the path to the <Smart Instrumentation home folder>\DDP\Output folder.
-
Do one of the following:
-
To append data that you exported from Smart Instrumentation DDP to instrument specifications already in the project, select Load.
-
To delete any existing instrument specifications before loading, select Replace.
-
-
In the File Name box, type neutral.dat.
-
On the toolbar, select to load the instrument specifications to the reference database.
-
On the toolbar, select .
-
If your PDS project uses both unapproved and approved libraries, on the main Piping Job Specification Manager window select Unapprove ==> Approve. On the toolbar, select .
-
In response to the warning message that spec records will be overwritten, in the message box select OK, and on the toolbar, select .
-
On the toolbar, select .
-
In the Reference Data Manager, select Material Description Library Manager.
-
Select Specialty Description Library.
-
Under Specialty Material Description Library, do the following:
-
Select Load/Revise Interactive.
-
Under Types, select Instruments.
-
On the toolbar, select .
-
Under Specialty Material Description Library, do the following to load the material descriptions:
-
In the Node Name box, type the computer name for the <Smart Instrumentation home folder>\DDP\Output folder.
-
In the File Path box, type the path to the <Smart Instrumentation home folder>\DDP\Output folder.
-
In the File Name box, type mto.dat.
-
On the toolbar, select .
-
If your PDS project uses both unapproved and approved libraries, select Unapprove ==> Approve. On the toolbar, select .
-
On the toolbar, select .
-
In the Material Description Library Manager window, on the toolbar, select .
-
In the Reference Data Manager window, select Physical Data Library Manager.
-
Under Library/Data Management, do the following:
-
From the list to the right of the command buttons, select the practice (for example US Practice).
-
On the toolbar, select .
-
Do the following:
-
In the Node Name box, type the computer name for the <Smart Instrumentation home folder>\DDP\Output folder.
-
In the File Path box, type the path to the <Smart Instrumentation home folder>\DDP\Output folder.
-
-
Select Create / Interactive Data.
-
To the right of the command buttons, toggle the Single button to display List.
-
In the box to the right of List, type listfile.txt.
-
On the toolbar, select .
-
If your PDS project uses both unapproved and approved libraries, select Unapproved ==> Approved. On the toolbar, select .
-
On the toolbar, select .
-
In the Physical Data Library Manager window, under Library/Data Management, on the toolbar, select .
-
In the Reference Data Manager window, on the toolbar, select .
-
In the Plant Design System Environment window, select to exit PDShell.