Before you can view your plant metadata, you must follow this procedure to configure the Smart API server for connecting to your site.

  1. In the path where you installed the Smart Electrical server, navigate to the ConfigurationTool folder and right-click Intergraph.Configuration.Utility.exe.

  2. On the shortcut menu, click Run as administrator.

  3. In the Smart Configuration Utility, click the SEL Module icon.

  4. In the left pane of the SEL MODULE SMART CONFIGURATION UTILITY window where the initial text Enter Site Name appears, type a name for your site and click Add.

    The name is copied to the Site Name field in the right pane:

    The site name you choose does not have to match the name of the actual site you will connect to via the SmartPlantV4.ini file.

  5. Beside the Ini path box, click the ellipsis and in the Open dialog box, navigate to the folder with the SmartPlantV4.ini file for the site you want to connect to.

  6. If you want to ignore data for a plant when sending Smart API requests, type the name of the plant in the Plant box and click Add. Do this for each plant for which you want the data to be ignored.

    A list of the excluded plants appears in the Exclude Plants field.

    The plant name you type must exactly match the name of a real plant in the site.

  7. If your plants configured for projects and you want to ignore data for a project when sending Smart API requests, type the name of the project in the Project box and click Add. Do this for each project for which you want the data to be ignored.

    A list of the excluded projects appears in the Exclude Projects field.

  8. Click Finish to save your changes and exit the Smart Configuration Utility or click Exit to exit without saving any changes.

These settings are saved in the customConfigSection.xml file located in the SEL WEB API\V folder in the installation path of the Smart Electrical server.