Data migration failure due to operation timing out - Intergraph Smart Construction - Hotfix 14 - Help - Hexagon

Intergraph Smart Construction Help

Language
English
Product
Intergraph Smart Construction
Search by Category
Help
Smart Construction Version
8
SmartPlant Foundation / SDx Version
10

Problem

When a large set of data is being migrated to a new version of Smart Construction, the Scheduler task for migrating the data fails due to a system timeout.

Solution

You can increase the default internal request timeout period. This can be done by updating the timeout setting in the property InternalRequestTimeout, which is a property on the SmartPlant Foundation Site Settings node. It may require experimentation with incrementally larger settings to determine the length of time needed to allow the operation to finish.

For more information on the InternalRequestTimeout property, see Site Settings node properties.