Below is a list of available user preferences in Smart Construction.
Option |
Preference |
More information |
---|---|---|
Maximum query limit |
Text box |
The query limit applies to components in a Quick Find and Get objects by volume tools in the model and drawing. The default value is 200. If you set a high query limit, performance is affected. |
Display drawing names as |
name only |
Smart Construction displays only the names of drawings. |
name and short description |
Smart Construction displays both the name and the short description of drawings. |
|
short description only |
Smart Construction displays only the short description of drawings. |
|
When I add a drawing to an IWP |
ask me what to do |
When you add a drawing to an IWP, Smart Construction sends you a message asking how you would like the components in the drawing to be added to the IWP. |
only add the drawing |
When you add a drawing to an IWP, only the drawing is added. Components associated with the drawing are not added to the IWP. |
|
add all individual components |
When you add a drawing, both the drawing and the individual components in the drawing are added to your IWP. |
|
add components as spools/assemblies when possible |
When a drawing is added to an IWP that contains spools or assemblies, spools or assemblies are added to the IWP as single components (not multiple components). When you add a spool to an IWP or view a spool in a model or drawing, Smart Construction treats the spool as it was modeled in the authoring tool. For example, if supports were included as part of a spool, Smart Construction adds supports to an IWP as part of the spool and displays the supports as part of the spool. |
|
When I remove all components on a drawing from an IWP |
ask me what to do |
When you remove all components from an IWP, Smart Construction sends you a message asking if you would also like to remove the drawing from the IWP. |
always remove the drawing |
When you remove all components from an IWP, Smart Construction also removes the associated drawing. |
|
leave the drawing on the IWP |
When you remove all components from an IWP, Smart Construction leaves the associated drawing in the IWP. |
|
Warn when adding components with a different discipline than the IWP. |
Yes/No |
Smart Construction would notify you when you try to add components of one discipline to an IWP of another discipline. |
Warn when adding components with a different CWP than the IWP. |
Yes/No |
Smart Construction would notify you when you try to add a component associated with one CWP to an IWP associated with another CWP. |
Warn when marking or clearing complete progress for the package. |
Yes/No |
Smart Construction would notify you when you try to mark or clear the complete progress of an IWP. |
When I attach files to an IWP, ask me what to do |
Yes/No |
When you attach a file to an IWP, you can decide how files are attached to IWPs. You can decide to include the files in reports or not. Or, you can decide to use the system setting for the file. The file is attached according to how your system administrator configured file preferences. |
Show the list of related documents when components are added to an IWP. |
Yes/No |
When configured, you can specify whether or not to be prompted about which files are added to an IWP. |