  1. Browse to the Component Registers folder in the Templates folder of the installation location. For example, browse to [Drive]:\Program Files (x86)\SmartConstruction\2019\Templates\Component Registers.

  2. Open the component register template in Microsoft Excel.

  3. Enable the macro content for the workbook.

    1. On the Security Warning bar, click Options.

    2. Select Enable this content on the Microsoft Office Security Options, and click OK.

  4. Specify details for the register on the [Register name] tab. For more information, see Structure of the component register template and Delivered SmartPlant Construction component register templates.

    For information about adding custom properties to the register templates, see Add custom properties to register templates.

  5. Specify details for the register on the Data tab.

    • The column headers are specified in row 6, and the data of the register start at row 7.

    • The tag name must be unique for each tag in the register template.

    • The unit must be spelled the exact same (with same capitalization) as the unit specified on the Register Syntax tab.

    • Type a description in the Description column of the Generic Register, Cable Description column of the Cable Schedule register, or Column Description column of the Instrument Index register to associate material items in the Material Request form. The tag item description is used as the material description in the Material Request form.

    • If you need to delete a column on the Data tab, select the entire column and delete it from the tab.

  6. Open the Main tab.

  7. Specify a document name in the Document Name box.

    • The document name can be a string value containing 100 characters or less.

    • The document name cannot contain special characters * ' % ? ".

  8. Specify a document revision in the Document Revision box.

    • The document revision number must be greater than 0.

    • Document revision numbers should be specified in sequential order.

  9. Select the Is this the first revision? box to indicate if the register is the first revision.

    Clear the Is this the first revision? box if the register is not the first revision.

  10. Click Save to save your register details.

  11. Click Generate File to generate the output file in the same folder as the register workbook.