Displays properties for pipe surface mount features. A pipe surface mount feature is the high-level design object that contain information about objects that are attached to the outside of a pipe run such as ultrasonic flow meters or penetration sleeves.

The order in which the properties display in your view depends on your configuration.

Approval State

Specifies the status of the selected object or filter. Changing this property sets the Status. The display depends on your access level. You might be unable to change the status of the object. The list is defined by the ApprovalStatus codelist.

Smart 3Dx saves an object to the database when you change that object's status. Use Undo (CTRL + Z) to reverse the status change.

You can only edit or manipulate an object with a status of Working.

Coating Color

Specifies the color of the object coating. To change the options on the list, edit the Coating Color select list in Catalog. Smart 3Dx includes this property in the painting area report.

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.

Commodity Option

Specifies short code for the primary commodity object from the Piping job specification.

Correlation Approval Status

Specifies whether the object is approved with discrepancies in the three-dimensional data compared with design basis data. The list is defined by the EFWCorrelationApprovalStatus sheet in the AllCodelist workbook.

Topology mismatch approved

Indicates that the object topology mismatch can be ignored.

Data and Topology mismatches approved

Indicates that the object data and topology mismatches can be ignored.

None

Indicates that you do not approve a mismatch.

Correlation Basis

Specifies whether the object is correlated to a P&ID object. The list is defined by the EFWCorrelationBasis select list.

Correlate Object

Indicates that the object has a correlating object in a P&ID.

No correlation is required

Indicates that the object does not have a correlating object in a P&ID.

Correlation Status

Specifies whether the object has been correlated to an object in a P&ID. The list is defined by the EFWCorrelationStatus select list.

Created by

Specifies the name of the person who created the object.

Date Created

Specifies the creation date of the object.

Date Last Modified

Specifies the date of the last modification to the object.

Exterior Coating Area

Specifies the area of the coating for the object.

Exterior Coating Requirement

Specifies the coating requirement for the object. To change the options on the list, edit the Coating Type select list in Catalog.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

Exterior Coating Type

Specifies the type of coating for the object. To change the options on the list, edit the Exterior Coating Type select list in Catalog.

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.

Hyperlink

Specifies the URL or local file path associated with the object. Click the hyperlink to open the page or object in your default browser. Point to the hyperlink to display the URL or path as a tooltip.

Description

Specifies the descriptive text associated with the hyperlink.

URL

Specifies the web address or local file name associated with the hyperlink. The URL must include the protocol, such as http: or https:, as well as the domain name. For example, https://hexagonppm.com/.

Insulation Material

Specifies the material of the insulation.

Piping

The software displays this property only when the Insulation Type is Specification Driven or User Defined.

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value. This option displays when the Insulation Type is Specification Driven.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven . This option displays when the Insulation Type is User Defined.

User Driven

Allows you to select a value. Click to switch to Rule Driven .

This option displays when the Insulation Type is User Defined.

The User Driven option is not active if it is not present on the parent pipe run.

HVAC

If you select Not Insulated, you cannot change the information in Insulation Thickness.

Select More to select an insulation material from the Catalog. To change the options on the list, edit the Insulation Material select list in Catalog. See Select Insulation Material Dialog.

Insulation Purpose

Specifies the purpose of insulation. The software displays this property only when the Insulation Type is Specification Driven or User Defined. To change the options on the list, edit the Insulation Purpose select list in Catalog.

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value. This option displays when the Insulation Type is Specification Driven.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven . This option displays when the Insulation Type is User Defined.

User Driven

Allows you to select a value. Click to switch to Rule Driven .

This option displays when the Insulation Type is User Defined.

The User Driven option is not active if it is not present on the parent pipe run.

Insulation Specification

Specifies the insulation specification for the object. The software displays this property only when the Insulation Type is Specification Driven.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

The User Driven option is not active if it is not present on the parent pipe run.

Insulation Temperature

Specifies the temperature. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example) when specifying this value. The software displays this property only when the Insulation Type is User Defined or Specification Driven.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

The User Driven option is not active if it is not present on the parent pipe run.

Insulation Thickness

Specifies the thickness of the insulation.

Piping

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value. This option displays when the Insulation Type is Specification Driven.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven . This option displays when the Insulation Type is User Defined.

User Driven

Allows you to select a value. Click to switch to Rule Driven .

This option displays when the Insulation Type is User Defined.

The User Driven is not active if:

  • It is not present on the parent pipe run.

  • The Insulation Material on pipe feature does not support the value of the Insulation Thickness on pipe run.

HVAC

If you selected Not Insulated in the Insulation Material box, this property is unavailable.

Insulation Type

Specifies the type of the insulation.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

Interior Coating Area

Specifies the area of the interior coating for the object.

Interior Coating Requirement

Specifies the area of the interior coating for the object.

Is Flipped

Specifies whether the surface mounted feature is flipped.

Last Modified by

Specifies the name of the person who last modified the object.

NPD

Specifies the nominal piping diameter for the object. If displays in the box, the nominal diameter is derived from a rule and not editable. If the icon does not display, the value is user defined.

NPD Unit Type

Specifies the units for the NPD value. Select mm or in from the list.

Outer Diameter

Specifies the outer diameter of the object.

Rotation Angle

Specifies the rotation of the cross-section about its local axis.

Tag

Specifies a tag that identifies the object.

Type

Specifies the path feature type.