HVAC Nozzle Properties (No Added Graphic) - Intergraph Smart 3D - Help - Hexagon PPM

Intergraph Smart 3Dx Property Descriptions

Language
English
Product
Intergraph Smart 3D
Subproduct
3Dx
Search by Category
Help
Smart 3D Version
13

Displays properties for HVAC nozzles. An HVAC nozzle is the connect point between duct parts and equipment. The nozzle contains definitions of the connection like flow direction, duct cross-section, and size.

The order in which the properties display in your view depends on your configuration.

Approval State

Specifies the status of the selected object or filter. Changing this property sets the Status. The display depends on your access level. You might be unable to change the status of the object. The list is defined by the ApprovalStatus codelist.

Smart 3Dx saves an object to the database when you change that object's status. Use Undo (CTRL + Z) to reverse the status change.

You can only edit or manipulate an object with a status of Working.

Behavior Controlled by User

Specifies whether you can delete the object or not. Select False to prevent anyone from deleting the object from the model.

Construction Requirement

Specifies the construction requirement for the object. To change the options on the list, edit the Construction Requirement select list in Catalog.

Construction Type

Specifies the type of construction for the object. To change the options on the list, edit the Construction Type select list in Catalog.

Correlation Approval Status

Specifies whether the object is approved with discrepancies in the three-dimensional data compared with design basis data. The list is defined by the EFWCorrelationApprovalStatus sheet in the AllCodelist workbook.

Topology mismatch approved

Indicates that the object topology mismatch can be ignored.

Data and Topology mismatches approved

Indicates that the object data and topology mismatches can be ignored.

None

Indicates that you do not approve a mismatch.

Correlation Basis

Specifies whether the object is correlated to a P&ID object. The list is defined by the EFWCorrelationBasis select list.

Correlate Object

Indicates that the object has a correlating object in a P&ID.

No correlation is required

Indicates that the object does not have a correlating object in a P&ID.

Correlation Status

Specifies whether the object has been correlated to an object in a P&ID. The list is defined by the EFWCorrelationStatus select list.

Created by

Specifies the name of the person who created the object.

Cross Section Shape

Specifies the shape of the object cross section.

Corner Radius

Specifies the radius of the cross-section and is available for the Rectangle shape.

Depth

Specifies the depth for the section. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Width

Specifies the flange width for the section. This property is read-only. To edit this value, you need to edit the cross-section's properties in Catalog or in the corresponding workbook.

Diameter

Specifies the diameter of the cross-section and is available for the Round shape.

Date Created

Specifies the creation date of the object.

Date Last Modified

Specifies the date of the last modification to the object.

Dimension Base Outer

Specifies the outer dimension of the base of the nozzle.

Distribution Port Status

Specifies the distribution port status for the object. To change the options on the list, edit the Distribution Port Status select list in Catalog.

Distribution Port Type

Specifies the distribution port type for the object. To change the options on the list, edit the Distribution Port Type select list in Catalog.

End Preparation

Specifies the end preparation code for the part port. To change the options on the list, edit the End Preparation select list in Catalog.

Fabrication Requirement

Specifies the fabrication requirement for the object. To change the options on the list, edit the Fabrication Type select list in Catalog.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

Flange Projection or Socket Offset

Specifies the projection of the flange or offset of the socket for the object.

Flange Projection or Socket Offset CONCEPT

Flange Width

Specifies the width of the flange of the object.

Flow Direction

Specifies the flow direction for the duct run. The flow directional indicators are listed below:

Bi-directional

Upstream

Downstream

No flow

Undefined

Hyperlink

Specifies the URL or local file path associated with the object. Click the hyperlink to open the page or object in your default browser. Point to the hyperlink to display the URL or path as a tooltip.

Description

Specifies the descriptive text associated with the hyperlink.

URL

Specifies the web address or local file name associated with the hyperlink. The URL must include the protocol, such as http: or https:, as well as the domain name. For example, https://hexagonppm.com/.

IsConnected

Indicates whether the nozzle is connected.

Last Modified by

Specifies the name of the person who last modified the object.

Name

Specifies the name of the selected object. If the name is too long to entirely display in the box, point to the box to display the complete name as a tool tip. If the name is not defined by a rule, User Defined displays. If this name is generated by a naming rule, Naming Rule displays. If you type a name in this box, Smart 3Dx automatically changes the naming rule to User Defined.

Nozzle Length

Specifies the measurement for the nozzle length.

Nozzle Length CONCEPT

Orientation

Specifies the orientation for the object with respect to the local coordinate system. Use the Bearing, Pitch, and Roll properties to change the orientation of the selected object.

Permission Group

Specifies the permission group to which the object belongs. You can select another permission group, if needed. Permission groups are created in Project Management.

Placement Type

Specifies a location type for the nozzle. The following location types are available for nozzles:

S3D_Equipment_Nozzle_Orientation_Radial Radial

Straight nozzle with nozzle centerline on the radial plane.

S3D_Equipment_Nozzle_Orientation_Tangential Tangential

Straight nozzle on the radial plane, but the nozzle centerline does not intersect the vessel axis.

S3D_Equipment_Nozzle_Orientation_Axial Axial

Straight nozzle normal to radial plane.

S3D_Equipment_Nozzle_Orientation_Skew Skew

Straight nozzle that is tilted from both the radial plane and the vessel axis.

Axial Equipment Nozzle Elbow Orientation Axial Elbow

Elbow nozzle with hub centerline normal to the radial plane.

S3D_Equipment_Nozzle_Elbow_Orientation_Radial Radial Elbow

Elbow nozzle placed with the hub radial to the vessel axis.

S3D_Equipment_Nozzle_Elbow_Orientation_OffsetRadial Offset Radial Elbow

Elbow nozzle placed with the hub tangential to the vessel axis.

S3D_Equipment_Nozzle_Orientation_OffsetSkew Offset Skew

Skew nozzle with a parallel offset in the radial plane.

S3D_Equipment_Nozzle_Orientation_PositionByPlaneandAxis Position by Plane and Axis

Places the nozzle at the intersection of the selected plane and axis. Available only for nozzles that have the same shape or design solid as the orientation reference.

S3D_Equipment_Nozzle_Orientation_PositionByPoint Position by Point

Places the nozzle at the location you select with respect to the active coordinate system. Available with all Nozzles including PipePort (No Added Graphic) and HvacPort (No Added Graphic).

N1

Specifies the axial distance from the reference point along the x-axis.

N2

Specifies the distance from the reference object point to the face of the nozzle or port. This is an unsigned offset along the positive direction of the radial.

N3

Specifies the radial distance to the hub centerline. This is an unsigned offset along the positive direction of the radial.

OR1

Specifies the angle around the reference object point measured from the y-axis of the object (y-axis is 0°) or the Y-axis of the coordinate system.

OR1 measured to Active Coordinate System North

Calculates the OR1 angle value with respect to the active coordinate system north. This property is available when the X-axis of the orientation reference is parallel to the Z-axis of the active coordinate system. If a nozzle satisfies this condition, select OR1 measured to Active Coordinate System North and finish the command to save the new value in the session preferences. The next time you select or create a nozzle, the software calculates the OR1 angle value based the last saved preference. Because this is a session preference, this value applies to all of the nozzles in the System Hierarchy Explorer.

OR2

Specifies the orientation of the flange center line as rotated about the vessel axis, starting from the radial arrow.

Port Depth

Specifies the depth of the port.

Port Index

Specifies the index number for the port.

Position

Specifies the intersection point of the object to the axis. Use the East, North, and Elevation properties to change the position.

Reporting Requirement

Specifies the reporting requirement for the object. To change the options on the list, edit the Reporting Type select list in Catalog.

Reporting Type

Specifies the type of reporting. To change the options on the list, edit the Reporting Type select list in Catalog.

Thickness

Specifies the thickness of the object.