Meaning: Collinear members connected with a splice connection must have the same rotation and mirror value. One member was placed with a different rotation/mirror value or modified to have different values.

Recovery: Edit both collinear members to make their rotation and mirror values the same.

  1. Set the Locate Filters to Member Parts .

  2. Select one of the members.

  3. Note the Angle and Reflect settings on the Properties View.

  4. Select the other member and define the same Angle and Reflect settings for it.