Axis-end frame connection is missing the supporting member information. Change connection to unsupported and then re-select the supporting member. - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3Dx Help

Language
English
Product
Intergraph Smart 3D
Subproduct
3Dx
Search by Category
Help
Smart 3D Version
13

Meaning: The axis-end member's supporting member was not provided, resulting in improper placement of the axis-end connection. This error is an internal software failure where the software did not properly call the frame connection with its required inputs.

Recovery:

  1. Select the frame connection in error.

  2. Select By Rule from the Connection box in the Properties View.

  3. Redefine the end location of the member.