Add a ducting nozzle to equipment - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3Dx Help

Language
English
Product
Intergraph Smart 3D
Subproduct
3Dx
Search by Category
Help
Smart 3D Version
13
  1. Selectthe parent equipment for the nozzle.

  2. Select Ducting Nozzle Equipment HVAC Nozzle at the bottom of Place Equipment Controls to display the Insert Nozzle or Port Controls.

    Select Ducting Nozzle command conecept

  3. Verify the selected equipment (Parent System) for the nozzle and the nozzle name are correct.

  4. Select Orientation Properties S3D_Nozzle_Orientation.

  5. Under Orientation Reference, select Select orientation reference.

    Click Select orientation reference

  6. Select a shape on the equipment. Nozzle locations are measured from the selected shape origin and is indicated by a triad and a nozzle in dynamics.

    Orientation Reference Point Ducting Nozzle CONCEPT

  7. Select a Placement Type.

  8. Select preview to see the dimensions for the selected Placement Type.

  9. Enter nozzle orientation distances and angles as shown in the preview. These values define the nozzle location on the equipment.

  10. Select Dimensional Properties Dimensional Data.

  11. Selet preview to see the nozzle dimensions.

  12. Enter the nozzle dimensions. These values define the size of the nozzle itself.

  13. Complete the placement:

    • Select Finish or press CTRL + ENTER to save your changes and exit the command.

    • Select Finish and Modify Finish Modify ICON or press CTRL + SHIFT + ENTER to save your changes, and then start the modification of that object.

    • Select Finish and Repeat Finish Repeat ICON or press SHIFT + ENTER to save your changes, and then restart the command using the same options.