No intersection for this landing curve. Delete the curve or modify the inputs so an intersection exists. - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3Dx Help

Language
English
Product
Intergraph Smart 3D
Subproduct
3Dx
Search by Category
Help
Smart 3D Version
13

Meaning: Failed to find an intersection for this landing curve. The inputs are not intersecting each other in order to determine the intersection.

Or, the Delete Seam option was not selected in the Planning Merge command (Two blocks were merged, but the operator decided to send the seam to the To Do List instead of having the seam deleted.)

Recovery: Re-define the landing curve by verifying that the inputs still intersect and make any necessary changes. If problem still exits, report steps taken to your support group.