Meaning: Two end ports were expected as input and the count was not two, resulting in incorrect placement of the gusset connection. This error is an internal software failure.
Recovery:
-
Open the Structure task.
-
Click Select .
-
Set the Locate Filter to Member Assembly Connections.
-
Select the assembly connection in error.
-
Click Delete .
-
Click Place Assembly Connection .
-
Select the frame connection.
-
Clear the By Rule option.
-
Select More from the Type box.
-
Select Member by Member Assembly Connection > Gusset Plate Assembly Connection > GussetPlateAsmConn_1.
-
Click OK.
-
Click Finish.