Meaning: The boundary objects for the tripping stiffener are not valid, have been modified, or are missing.

Recovery:

  1. Select the tripping stiffener in the To Do List, and check the boundary inputs.

  2. Provide any missing inputs, or reselect the inputs. Verify that the connection type is valid for the given case.

  3. Verify that the connect point data is valid in the tripping stiffener properties.

  4. If these steps do not resolve the issue, try removing and replacing the tripping stiffener.