You can link directly to this document using https://docs.hexagonppm.com/go/S3D11Troubleshooting
The following changes have been made to the Troubleshooting Guide.
Service Pack and Hot Fix Updates
-
Version 2016 (V11) is the last version to support .CAB files. Version 2018 (V12) will not support .CAB files. (P3 CP:319755)
-
Added a new message in the Hole Management To Do List messages. See No intersection is found between ‘Outfitting/Equipment Hole Aspect’ and ‘Structure(s)’. Please revise inputs. (P3 CP: 375004)
-
Updated Run database administration processes with the following:
-
Added information about the performance impacts when attaching and detaching large Reference 3D (R3D) models to a Smart 3D model in Project Management.
-
Added guidelines for when to stop the Smart 3D Rule Checker service before performing database intensive tasks.
-
Version 2016 (11.0)
-
Updated Sources of Errors with information on .NET symbols with duplicate output names. For more information, see Troubleshooting Symbols.
-
This guide now lists the correct maximum number of characters you can use when naming part classes for both Microsoft SQL Server and Oracle databases. For more information, see Error Messages: T.
-
Added two new error messages for Common Route. For more information, see Error Messages: Y.
-
Added six new error messages for Civil, pertaining to turn feature length, turn rules, symbol computation, segment depth, and ProjectionX and ProjectionY values. For more information, see Error Messages: A, Error Messages: N, Error Messages: S, and Error Messages: T. (P2 CP:253007)
-
Updated To Do List messages for the Common task. For more information, see Common To Do List Messages. (P2 CP:192589)
-
Updated To Do List messages for the Molded Forms task. For more information, see Molded Forms To Do List Messages.(P2 CP:269881)
-
Updated To Do List messages for the Compartmentation task. For more information, see Compartmentation To Do List Messages. (P2 CP:277473)
-
Replaced "The line topology is invalid. No more than two parts associated with the same run can be connected to a component" To Do List message with "Single pipe run traverses three ports of a branching condition. This will cause problems correlating to P&ID where the same situation is not allowed." For more information, see Single pipe run traverses three ports of a branching connection. This will cause problems correlating to P&ID where the same situation is not allowed.. (P3 CP:263983)
-
Updated the Enable Error Log dialog box. For more information, see Error Logging. (P3 CP:275291)
-
Removed the error message "Object has no proper interface type declared for collision detection." (P3 CP:297040)
-
Added one error message and edited one error message to reflect the removal of the CasPol .exe file from the software. For more information, see Error Messages: E. (P3 CP:297040)
-
Add the To Do List messages for the Civil task. For more information, see Civil To Do List Messages.
-
Updated To Do List messages for the Hangers and Supports task. For more information, see Hangers and Supports To Do List Messages. (P4 CP: 274556)
-
Updated To Do List messages for the Equipment task. For more information, see Equipment To Do List Messages. (P4 CP:274558)
-
Updated To Do List messages for the Structural Detailing task. For more information, see Structural Detailing To Do List Messages. (P4 CP:274556)
-
Added information about deferring cable length and tray fill calculations. See Electrical. (P2 CP: 370519)
-
Added a new message in the Piping, HVAC, and Electrical To Do List messages. See Cable is out of date. Needs to be recomputed (see Cable is out of date. Needs to be recomputed). (P2 CP: 370519)