Unknown error. Delete and replace. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
11 (2016)

Meaning: An ill-define corner cope feature. This error is an internal software failure.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Member Assembly Connections.

  4. Select the corner brace assembly connection in error.

  5. Click Delete ICON Remove.

  6. Replace the corner cope feature.