Standard
Name
Displays the name of the pipeline. The pipeline name is based on the Name Rule selection. If you specify a name in this box, the software automatically sets the Name Rule box to User Defined.
Name Rule
Specifies the naming rule to use to name this pipeline. You can select one of the listed rules or specify the pipeline name yourself in the Name box.
Specification
Identifies the pipe specification the software uses to control this pipe run. Only those pipe specifications that are allowed in the pipeline that you selected appear in this list. You assign pipe specifications to pipeline systems in the System and Specifications task. You define pipe specifications in the reference data. See the Piping Reference Data Guide for more information on defining pipe specifications.
Minimum Slope
Displays the slope for the pipe run. You can specify the slope as a ratio, a percentage, or in degrees.
-
As a ratio, if a run drops 1/4" for every foot of horizontal distance, specify the slope as 1/4"/1'-0".
-
As a percentage, if a run drops 1" for every 10" of horizontal distance, specify the slope as 10%.
-
In degrees, a five-degree slope can be specified as 5deg.
Nominal Diameter
Specifies the nominal pipe diameter (NPD) for the pipe run. The pipe specification controls the available NPDs in this list. If you select an equipment nozzle as the starting point of your pipe run, the software automatically uses the NPD of the nozzle as the NPD of the pipe run. You can select the NPD units to display on a session file basis using the Tools > Options command on the Units of Measure tab.
Description
Specifies the description assigned to the selected pipeline system when it was created.
Sequence Number
Specifies the identification number assigned to the selected pipeline system when it was created.
Fluid Requirement
Specifies the alternative fluid requirement for the pipeline system. You can select an alternative fluid requirement from the list.
Fluid Type
Specifies the fluid type for the pipeline system. You can select a fluid type from the list.
Responsibility
Cleaning Responsibility
Specifies the party responsible for cleaning the object. To change the options on the list, edit the Cleaning Responsibility select list in Catalog.
Design Responsibility
Specifies the party responsible for designing the object. To change the options on the list, edit the Design Responsibility select list in Catalog.
Fabrication Responsibility
Specifies the party responsible for fabricating the object. To change the options on the list, edit the Fabrication Responsibility select list in Catalog.
Installation Responsibility
Specifies the party responsible for installing the object. To change the options on the list, edit the Installation Responsibility select list in Catalog.
Painting Responsibility
Specifies the party responsible for painting the object. To change the options on the list, edit the Painting Responsibility select list in Catalog.
Requisition Responsibility
Specifies the party responsible for ordering the object. To change the options on the list, edit the Requisition Responsibility select list in Catalog.
Supply Responsibility
Specifies the party responsible for delivering the object. To change the options on the list, edit the Supply Responsibility select list in Catalog.
Testing Responsibility
Specifies the party responsible for testing on the object. To change the options on the list, edit the Testing Responsibility select list in Catalog.
Insulation and Tracing
Insulation Specification
Specifies the insulation specification for the object. If Inherited Properties or Spec displays in the box, the insulation specification for the object is inherited from the pipe run to which the object belongs.
Defines which insulation specifications are available for which systems in System and Specifications. Insulation specifications are defined in the reference data.
Not Insulated
Disables the remaining insulation properties.
User Defined
Indicates that you can specify the remaining insulation properties using custom settings.
More
Displays a dialog so that you can select an insulation specification from the reference data. The software then automatically enters information from that insulation specification.
Insulation Purpose
Specifies the purpose of the insulation. If you selected Not Insulated in the Insulation Specification box, you cannot change the information in the Insulation Purpose box. However, if Insulation Specification is manually defined, you can select the purpose of the insulation in this box. If Insulation Specification is a selected reference data insulation specification, the software reads the purpose from the insulation specification from the reference data and displays it here.
To change the options on the list, edit the Insulation Purpose select list in Catalog.
Insulation Material
Specifies the material of the insulation.
Piping
If you selected Not Insulated in the Insulation Specification box, you cannot change the value in the Insulation Material box. However, if you manually entered the insulation specification, you must provide a corresponding insulation material as per the specification. If you selected an insulation specification from the available list, the software automatically displays the corresponding material as per the specification.
HVAC
If you select Not Insulated, you cannot change the information in Insulation Thickness.
Select More to select an insulation material from the Catalog. To change the options on the list, edit the Insulation Material select list in Catalog. See Select Insulation Material Dialog.
Insulation Thickness
Specifies the thickness of the insulation.
Piping
If you selected Not Insulated in the Insulation Specification box, you cannot change the value in the Insulation Thickness box. However, if you manually entered the insulation specification, you must provide a corresponding insulation thickness value as per the specification. If you selected an insulation specification from the available list, the software automatically displays the corresponding thickness value as per the specification.
HVAC
If you selected Not Insulated in the Insulation Material box, this property is unavailable.
Insulation Temperature
Specifies the temperature. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example) when specifying this value.
Heat Tracing Requirement
Specifies whether the object is heat-traced. To change the options on the list, edit the Heat Tracing Medium select list in Catalog.
Heat Tracing Type
Specifies the type of heat-tracing. To change the options on the list, edit the Heat Tracing Medium select list in Catalog.
Heat Tracing Medium
Specifies the heat-tracing medium to apply to the object. To change the options on the list, edit the Heat Tracing Medium select list in Catalog.
Heat Tracing Medium Temperature
Specifies the temperature of the heat-tracing medium. Include the unit of measurement of temperature (K for Kelvin, F for Fahrenheit, or C for Celsius, for example).
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.
Surface Treatment and Coating
Interior Surface Treatment Requirement
Specifies the interior treatment requirement for the object. To change the options on the list, edit the Interior Surface Treatment select list in Catalog.
Interior Surface Treatment Type
Specifies the interior treatment type for the object. To change the options on the list, edit the Interior Surface Treatment select list in Catalog.
Exterior Surface Treatment Requirement
Specifies the exterior treatment requirement for the object. To change the options on the list, edit the Exterior Surface Treatment select list in Catalog.
Exterior Surface Treatment Type
Specifies the exterior treatment type for the object. To change the options on the list, edit the Exterior Surface Treatment select list in Catalog.
Cleaning Requirement
Specifies the cleaning requirement for the object. To change the options on the list, edit the Cleaning Requirement select list in Catalog.
Steamout Requirement
Specifies the steamout requirement for the object. To change the options on the list, edit the Steamout Requirement select list in Catalog.
Steamout Pressure
Specifies the steamout pressure for the object. Include the pressure unit of measure (psi for pounds per square inch for example).
Steamout Temperature
Specifies the steamout temperature for the object. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example).
Auxiliary Treatment Requirement
Specifies the auxiliary treatment requirement. To change the options on the list, edit the Auxiliary Treatment select list in Catalog.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .
User Driven
Allows you to select a value. Click to switch to Rule Driven .
Auxiliary Treatment Type
Specifies the auxiliary treatment type for the object. To change the options on the list, edit the Auxiliary Treatment select list in Catalog.
Interior Coating Requirement
Specifies the interior coating requirement for the object. To change the options on the list, edit the Coating Type sheet in the AllCodeLists.xls workbook in the reference data.
Interior Coating Type
Specifies the type of interior coating for the object. To change the options on the list, edit the Coating Type sheet in the AllCodeLists.xls workbook in the reference data.
Interior Coating Area
Specifies the area of the interior coating for the object.
Exterior Coating Requirement
Specifies the coating requirement for the object. To change the options on the list, edit the Coating Type select list in Catalog.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .
User Driven
Allows you to select a value. Click to switch to Rule Driven .
Exterior Coating Type
Specifies the type of coating for the object. To change the options on the list, edit the Exterior Coating Type select list in Catalog.
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.
Exterior Coating Area
Specifies the area of the coating for the object.
Coating Color
Specifies the color of the object coating. To change the options on the list, edit the Coating Color select list in Catalog. Smart 3D includes this property in the painting area report.
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.
Testing
Testing Requirements
Specifies the type of non-destructive testing required for welds. To change the options on the list, edit the Testing Type select list in Catalog.
Testing Type
Specifies the type of non-destructive weld testing for the welds. To change the options on the list, edit the Testing Type select list in Catalog.
Testing Percentage
Specifies the percentage of the welds on this pipe run that are to be tested. This option is available only if you are viewing pipe run properties.
Temperature and Pressure
-
Temperature and pressure values are controlled by UndefinedServiceLimitsruleOpt, which is available on the DefaultProjectOptions sheet in the Piping Specification.xls workbook. If this option is set to 5, then you must specify temperature and pressure values for all the pipe runs. If this option is set to 10, the software displays a warning: "No Temperature and pressure data has been defined for the pipe run being modeled. As a result, compliance with the temperature/pressure service limits as defined in the piping specification cannot be confirmed. Do you want to continue modeling the pipe run anyway?"
-
If your pipe specifications are material-driven, it is still recommended that you specify at least one set of temperature and pressure values for the pipe run.
Design Maximum Temperature
Specifies the maximum design temperature. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example).
Design Minimum Temperature
Specifies the minimum design temperature. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example).
Design Maximum Pressure
Specifies the maximum design pressure. Include the pressure unit of measure (psi for pounds per square inch for example).
Operating Maximum Temperature
Specifies the maximum operating temperature. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example).
Operating Minimum Temperature
Specifies the minimum operating temperature. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example).
Operating Maximum Pressure
Specifies the maximum operating pressure. Include the pressure unit of measure (psi for pounds per square inch for example).
Testing Maximum Temperature
Specifies the maximum testing temperature. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example).
Testing Minimum Temperature
Specifies the minimum testing temperature. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example).
Testing Maximum Pressure
Specifies the maximum testing pressure. Include the pressure unit of measure (psi for pounds per square inch for example).
Design Minimum Pressure
Specifies the minimum design pressure. Include the pressure unit of measure (psi for pounds per square inch for example).
Operating Minimum Pressure
Specifies the minimum operating pressure. Include the pressure unit of measure (psi for pounds per square inch for example).
Testing Minimum Pressure
Specifies the minimum testing pressure. Include the pressure unit of measure (psi for pounds per square inch for example).