Place vertical chevron bracing - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Structure

Language
English
Product
Intergraph Smart 3D
Subproduct
Structure
Search by Category
Help
Smart 3D Version
13

Show me

Place Vertical Chevron Bracing AGIF

  1. Click Place Bracing Command on the vertical toolbar.

  2. In the Bracing Type box, select Chevron.

  3. In the Type category box, select the chevron bracing member type category to place.

  4. In the Type box, select the chevron bracing member type to place.

  5. Set the Section Name, Cardinal Point, and Angle options as required.

    SHARED Tip You can set the beta angle relative to your rotated coordinate system by activating PinPoint and selecting the rotated coordinated system as the active coordinate system in the Coordinate System box.

  6. Select the first column to support the chevron bracing.

    SNAG_Program-0013

  7. Select the second column to support the chevron bracing.

    Place Vertical Chevron Bracing Second Column

  8. Select one beam to support the chevron bracing.

    Place Vertical Chevron Bracing First Beam

  9. Optionally, select a second beam.

    Place Vertical Chevron Bracing Second Beam

  10. Click Finish.

    Place Vertical Chevron Bracing Finished