The SimpleWindowAsm sheet in the SimpleDoor.xls workbook defines the windows that you want in your catalog. When creating simple windows, there are custom attributes and required attributes. You can add your custom attributes using the Custom Interfaces sheet (described in the Reference Data Guide.)

Name

Type a name for the window. The name must be unique across the entire catalog.

Part Description

Type a description for the window equipment part.

Symbol Definition

Type the definition of the Visual Basic symbol used to create the window. If you do not enter a value here, the symbol definition defined at the top of the sheet under Definition is used.

Symbol Icon

Enter the graphic to use when displaying a preview of the window equipment part in the Catalog task. If you do not enter a value here, the symbol icon defined at the top of the sheet under Definition is used.

Definition

Type the definition of the Visual Basic class you are creating for the custom assembly definition for the window.

Opening Ratio

Specify the opening rate of the window. Valid values are 1 (Open) and 0 (Closed).

Kinematics

Specify the overall motion of the window. Valid values are defined in the AllCodeLists.xls workbook on the Doors Windows Kinematics sheet in the Codelist column.

Push

Specify the sense of the window panel opening. Valid values are 1 (Push) and -1 (Pull)

Height

Enter the window height in millimeters.

Width

Enter the window width in millimeters.

Top Frame Depth

Specify the depth of the top window frame in millimeters.

Top Frame Width

Specify the width of the top window frame in millimeters.

Lower Frame Depth

Specify the depth of the lower window frame in millimeters.

Lower Frame Width

Specify the width of the lower window frame in millimeters.

Right Frame Depth

Specify the depth of the right window frame in millimeters.

Right Frame Width

Specify the width of the right window frame in millimeters.

Left Frame Depth

Specify the depth of the left window frame in millimeters.

Left Frame Width

Specify the width of the left window frame in millimeters.

Panel Thickness

Enter the thickness of the window panel in millimeters.

X Position

Type the X-position of the window related to the equipment coordinate system.

Y Position

Type the Y-position of the window related to the equipment coordinate system.

Z Position

Type the Z-position of the window related to the equipment coordinate system.

Dry Weight

Enter the empty weight of the window. Be sure to specify the units when entering this value.

Water Weight

Enter the water weight of the window. Be sure to specify the units when entering this value.

Dry COG X

Type the x-axis location of the dry center-of-gravity.

Dry COG Y

Type the y-axis location of the dry center-of-gravity.

Dry COG Z

Type the z-axis location of the dry center-of-gravity.

Water COG X

Type the x-axis location of the wet center-of-gravity.

Water COG Y

Type the y-axis location of the wet center-of-gravity.

Water COG Z

Type the z-axis location of the wet center-of-gravity.

Door Frame Position

Specify the position of the window frame within the specified support. Valid values are defined in the AllCodeLists.xls workbook on the Door Frame Position sheet in the Codelist column.

Distance from Mating Face

Specify the distance between the window and the wall/slab with which it is mated.

Number of Row Panes

Specify the number of row panes present in the window.

Number of Column Panes

Specify the number of column panes present in the window.