StructInsulationSpec Workbook - Intergraph Smart 3D - Reference Data - Hexagon PPM

Intergraph Smart 3D Structure Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Structure
Search by Category
Reference Data
Smart 3D Version
13

The StructInsulationSpec.xls workbook defines the insulation specifications used in the Place Fireproofing Command . The unique sheets in this workbook are described below. For more information on common sheets, see Describing the Common Sheets in the Workbooks in the Reference Data Guide.

Specification Name

Specifies the insulation specification name. All insulation specification names should be unique.

Specification Description

Specifies the insulation specification.

Purpose

Specifies the purpose of the insulation specification. The insulation specification purpose is defined in the StructInsulationPurpose select list in Catalog.

Material Name

Specifies the insulation material. This material is defined in Catalog in the Structure > Materials > Properties node.

Material Grade

Specifies the object material grade. To change the options on the list, edit the Structure > Materials > Properties node in Catalog.

Thickness

Specifies the insulation thickness.

Encasement Rule

Specifies the encasement rules that this insulation specification must use. Encasement rules are defined in Catalog in the Structure > Objects > Insulation > Fireproofing node or in the StructMemberFireproofing workbook.

Fireproofing Rating

Defines the time for which the fireproofing is rated.

See Also