This procedure describes setting up the full loopback between Smart 3D on the listener as a Windows Service and the nesting system (the client).

Because the listener only processes objects in the permission group of the local site, the integrity of the GWS model is not affected.

Start the Smart 3D LoopBack Listener service

  1. In Control Panel, click Administrative Tools, and then click Services. The main Services page displays.

  2. Click Intergraph Smart 3D LoopBack Listener Service, and then click Start to start the service. The Start option changes to Stop, as shown in the graphic below.

    If the Services page does not display Intergraph Smart 3D LoopBack Listener Service, you need to install the service. Follow the steps below to install and start the LoopBack Listener Service.

    1. Open the Command Prompt window and type the command below; press ENTER.

      installutil "[Product Folder]\Core\Container\Bin\Assemblies\
      Release\S3DLoopBackListener.exe"

    2. Enter the login information and confirm the password on the Set Service Login dialog box, and then click OK.

    3. In Control Panel, click Administrative Tools, and then click Services.

    4. Click Intergraph Smart 3D LoopBack Listener Service, and then click Start to start the service.

  3. Open Event Viewer and expand Applications and Services Logs to confirm that the service started successfully.