Hot Fixes and Service Packs Updates

  • The Select lists (Codelists) delivered with the software (AllCodeLists.xls) might be different than the codelists provided on the customer support web site. The most recent codelists available on the customer support web site should be used for the most current functionality. All select list documentation has been removed from this document.

  • Added information about the workbooks and codelists loaded by default into the catalog template. For more information, see Delivered Excel Workbooks, Marine Workbooks, and Materials Handling Workbooks. (P3 CP:338226)

  • Updated units of measure for mPag and kPag in Appendix: Units of Measure. (P4 CP:393205)

Version 2018 (12.0)

  • Added information about using Plant Design System (PDS) Reference Data Manager (PD_Data) independently to import PDS piping specification data into Smart 3D. For more information, see Extract Reference Data from PDS Reference Data Manager. (P2 CP:329849)

  • The maximum codelist name length for SQL Server is 254 characters. Previously, the SQL Server maximum codelist name length was 205 characters. For more information, see Appendix: Name Limitations in Reference Data. (P2 CP:320606)

  • Smart 3D no longer supports CAB files to deliver symbols and naming rules to client computers. All symbol and naming rule DLLs must be placed in the shared reference data share for access by the client computers. (P2 CP:311368)

  • A new Work Breakdown Structure (WBS) select list has been added: WBS Assignment Restriction. (P2 CP:300665)

  • Delta workbooks for version upgrade are no longer delivered with the software. (P2 CP:280184)

  • Removed references to plant content files which are not used to create the out-of-the-box catalog. These files are available on the customer support web site. (P2 CP:320719)

  • The Bulkload utility now restricts changes to the symbol share path for all modes except Bulkload to a new catalog. Previously, the Bulkload utility allowed changes to the symbol share path in Append, Add/Modify/Delete, and Delete/Replace modes. For more information, see Bulkload Utility. (P3 CP:310163)

  • Added references to the SmartPlant Reference Data Plus (SPRD) and SmartPlant Reference Data - Standard Database (SPRD-SDB) products. For more information, see Loading Reference Data into the Catalog and Appendix: Best Practices - Reference Data and Catalog Change Management.

  • Added information about bulkloading reference data to the catalog database. For more information, see Add in Bulkload Utility.

  • Added a note indicating that modifying the SolverProgID value for a Piping Specialty (CPRtePipeSpecialtyOcc) Naming Rule automatically changes the SolverProgID values for both the Piping Component (CPRteComponentOcc) and Instrument (CPRtePipeInstrumentOcc) Naming Rules as well. For more infomation, see Naming Rules Reference Data. (P4 CP:335831)