General Tab (Reference 3D Pipe Run Properties Dialog) - Intergraph Smart 3D - Help

Intergraph Smart 3D Piping

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Help
Smart 3D Version
12.1 (2019)
SmartPlant Foundation / SDx Version
10

Displays the standard properties of the Reference 3D pipe run. Reference 3D object properties are read-only.

Name

Displays the name of the pipe run.

Flow Direction

Displays the direction of the fluid flow for the pipe run.

Piping Materials Class

Displays the piping material class short code for the pipe run.

Nominal Diameter

Displays the nominal pipe diameter (NPD) of the pipe run.

Normal Design Temperature Max

Displays the maximum design temperature in unit of measure, K for Kelvin, F for Fahrenheit or C for Celsius.

Normal Design Pressure Max

Displays the maximum design pressure in unit of measure, psi for pounds per square inch.

Insulation Purpose 3

Displays the thickness of the insulation. The software reads the thickness from the insulation specification from the reference data and displays it here.

Insulation Composite Material

Total Insulation Thickness

Displays the thickness of the insulation. The software reads the insulation thickness for the material in the reference data.

Insulation Temperature

Displays the insulation temperature in unit of measure, K for Kelvin, F for Fahrenheit, or C for Celsius.

SP3D System Path

Layer Name

Displays the layer name on which the pipe run is contained.

Source object type

Displays the name of the type of piping object.