General Tab (Pipe Surface Mount Feature Properties Dialog) - Intergraph Smart 3D - Help

Intergraph Smart 3D Piping

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Help
Smart 3D Version
12.1 (2019)
SmartPlant Foundation / SDx Version
10

Displays and defines the general properties of the selected surface mounted component.

Pipe surface mounted component properties are divided into different categories: Standard, Insulation and Tracing, and Surface Treatment and Coating. You select which category that you want to define values for by using the Category option.

Standard

Pipeline

Displays the pipeline system to which the surface mounted component belongs. You cannot change the pipeline of the surface mounted component.

Pipe Run

Displays the pipe run to which the surface mounted component belongs. You cannot change the pipe run of the surface mounted component.

Specification

Specify the active pipe specification for the surface mounted component. All pipe specifications that are allowed for the pipeline display for selection. If appears in the box, the pipe specification is inherited from the pipe run to which the surface mounted component belongs. If the icon does not appear, and you want to use the pipe specification from the pipe run, select Use Run Specification.

Nominal Diameter

Specify the nominal diameter (NPD) of the surface mounted component. If appears in the box, the NPD for the surface mounted component is inherited from the pipe run to which the surface mount feature belongs. If the icon does not appear, and you want to use the pipe specification from the pipe run, select Use Run NPD. If you have manually selected the part, the NPD of the selected part appears and cannot be changed.

Type

Displays the types of surface mounted components allowed by the selected Specification and Nominal Diameter. Surface mounted components are listed by short codes. You can change the component type if needed. If you have manually selected the part from the catalog, Type displays as Part selected manually and cannot be changed.

Option

Displays a list of available surface mounted components. The software generates this list based on the pipe specification, the NPD, and the short code you selected in the Type box. If you have manually selected the part from the catalog, Option displays as Part selected manually and cannot be changed.

Base Part Name

Displays the part name for the surface mounted component. The part name is selected by the software using the pipe specification guidelines. Select Select Manually to override the pipe specification, and select the part number from the catalog. If you select a part manually, the Nominal Diameter, Type and Option properties are disabled.

The Select Manually option might not be available. It is enabled and disabled in the reference data.

Rotation Angle

Specifies the rotation angle of the surface mounted component around the pipe.

Correlation Status

Displays whether the surface mounted component has been correlated to a pipe end feature in a P&ID.

Correlation Basis

Specifies if the surface mounted component is correlated to a P&ID surface mounted component. Select Correlate object if the surface mounted component has a correlating surface mounted component in a P&ID. Select No correlation is required if the surface mounted component does not have a correlating pipe run in a P&ID.

Correlation Approval Status

Specifies if the surface mounted component is approved with discrepancies in the three-dimensional data compared with design basis data. Select Topology mismatch approved if the surface mounted component topology mismatch can be ignored. Select Data and Topology mismatches approved if the surface mounted component data and topology mismatches can be ignored. Select None if you do not want to approve a mismatch.

Insulation and Tracing

Insulation Specification

Specifies the insulation specification for the object. If Inherited Properties or Spec displays in the box, the insulation specification for the object is inherited from the pipe run to which the object belongs.

Defines which insulation specifications are available for which systems in System and Specifications. Insulation specifications are defined in the reference data.

Not Insulated

Disables the remaining insulation properties.

User Defined

Indicates that you can specify the remaining insulation properties using custom settings.

More

Displays a dialog so that you can select an insulation specification from the reference data. The software then automatically enters information from that insulation specification.

Insulation Purpose

Specifies the purpose of the insulation. If Insulation Specification is set to use the insulation defined by the equipment object, the information in this box cannot be changed. However, if Insulation Specification is manually defined, select the purpose of the insulation in this box. Available purposes are read from the reference data.

Insulation Material

Specifies the material of the insulation. If Insulation Specification is set to use the insulation defined by the equipment object, this field cannot be changed. However, if Insulation Specification is manually defined, select the insulation material from those available from the reference data.

The list contains the last five insulation materials selected. Select More to browse the catalog for the insulation material to use. If you set this field to Not Insulated, the Insulation Thickness field is disabled. If you set this field to Use Run Material, the along leg feature inherits the insulation material from the duct run.

To change the options on the list, edit the Insulation Material select list in Catalog.

Insulation Thickness

Specifies the thickness of the insulation.

Piping

If you selected Not Insulated in the Insulation Specification box, you cannot change the value in the Insulation Thickness box. However, if you manually entered the insulation specification, you must provide a corresponding insulation thickness value as per the specification. If you selected an insulation specification from the available list, the software automatically displays the corresponding thickness value as per the specification.

HVAC

If you selected Not Insulated in the Insulation Material box, this property is unavailable.

Insulation Temperature

Specifies the temperature. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example) when specifying this value.

Heat Tracing Requirement

Specifies whether the object is heat-traced. To change the options on the list, edit the Heat Tracing Medium select list in Catalog.

Heat Tracing Type

Specifies the type of heat-tracing. To change the options on the list, edit the Heat Tracing Medium select list in Catalog.

Heat Tracing Medium

Specifies the heat-tracing medium to apply to the object. To change the options on the list, edit the Heat Tracing Medium select list in Catalog.

Heat Tracing Medium Temperature

Specifies the temperature of the heat-tracing medium. Include the unit of measurement of temperature (K for Kelvin, F for Fahrenheit, or C for Celsius, for example).

Surface Treatment and Coating

Interior Surface Treatment Requirement

Specifies the interior treatment requirement for the object. To change the options on the list, edit the Interior Surface Treatment select list in Catalog.

Interior Surface Treatment Type

Specifies the interior treatment type for the object. To change the options on the list, edit the Interior Surface Treatment select list in Catalog.

Exterior Surface Treatment Requirement

Specifies the exterior treatment requirement for the object. To change the options on the list, edit the Exterior Surface Treatment select list in Catalog.

Exterior Surface Treatment Type

Specifies the exterior treatment type for the object. To change the options on the list, edit the Exterior Surface Treatment select list in Catalog.

Cleaning Requirement

Specifies the cleaning requirement for the object. To change the options on the list, edit the Cleaning Requirement select list in Catalog.

Steamout Requirement

Specifies the steamout requirement for the object. To change the options on the list, edit the Steamout Requirement select list in Catalog.

Steamout Pressure

Specifies the steamout pressure for the object. Include the pressure unit of measure (psi for pounds per square inch for example).

Steamout Temperature

Specifies the steamout temperature for the object. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example).

Auxiliary Treatment Requirement

Specifies the auxiliary treatment requirement. To change the options on the list, edit the Auxiliary Treatment select list in Catalog.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

Auxiliary Treatment Type

Specifies the auxiliary treatment type for the object. To change the options on the list, edit the Auxiliary Treatment select list in Catalog.

Interior Coating Requirement

Specifies the interior coating requirement for the object. To change the options on the list, edit the Coating Type sheet in the AllCodeLists.xls workbook in the reference data.

Interior Coating Type

Specifies the type of interior coating for the object. To change the options on the list, edit the Coating Type sheet in the AllCodeLists.xls workbook in the reference data.

Interior Coating Area

Specifies the area of the interior coating for the object.

Exterior Coating Requirement

Specifies the coating requirement for the object. To change the options on the list, edit the Coating Type select list in Catalog.

Rule Driven

Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .

User Driven

Allows you to select a value. Click to switch to Rule Driven .

Exterior Coating Type

Specifies the type of coating for the object. To change the options on the list, edit the Exterior Coating Type select list in Catalog.

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.

Exterior Coating Area

Specifies the area of the coating for the object.

Coating Color

Specifies the color of the object coating. To change the options on the list, edit the Coating Color select list in Catalog. Smart 3D includes this property in the painting area report.

Rule Controlled

Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.