Click Tools > PinPoint Command.
-
Select the Relative Tracking option on the PinPoint ribbon.
-
Select the Spherical Coordinates option on the PinPoint ribbon.
-
Click Route Pipe Command on the vertical toolbar.
-
Select the run starting point.
-
Define the pipe run properties on the New Pipe Run Dialog, and then click OK.
-
On the PinPoint ribbon, type the absolute distance and direction to route.
-
Click in the view to route the pipe run to the specified point. The software moves the PinPoint target to the new location.
-
Continue defining points as needed.
-
Select the ending point of the pipe run. Right-click to end a pipe run.
If the piping specification that you selected has service limits defined, you must define at least one temperature value and one pressure value for the pipe run. Do this by selecting Temperature and Pressure from the Category option.