Model from a P&ID - Intergraph Smart 3D - Help

Intergraph Smart 3D Piping

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Help
Smart 3D Version
12 (2018)
SmartPlant Foundation / SDx Version
10
  1. Click SmartPlant > Retrieve Command to retrieve the P&ID that contains the pipe to place. You can skip this step if the P&ID is already retrieved.

  2. Click SmartPlant > View P&ID Command to view the P&ID that contains the pipe to place.

  3. In the P&ID, select the point from which to start modeling. The point highlights in the model.

  4. Click Tasks > Piping to start the Piping task if necessary.

  5. Click Route Pipe Command . If the object from which you are routing is already correlated, the New Pipe Run Dialog displays with the parameters associated with the pipe run.

  6. Click OK to close the dialog..

  7. Route the pipe to meet your requirements.

  • You can insert components while you are routing pipe. With thRoute Pipe Command active, click Insert Component Command ., and then select the component from the P&ID. Click Finish on the Insert Component ribbon. The software inserts the component on the end of the run and then continues with the Route Pipe Command command. Do not right-click to reset the command, or you must restart the command.

  • You can insert components after you route pipe. Click Insert Component Command , select the run, and then select the component from the P&ID. Click Finish on the Insert Component ribbon to place the component in the model. If the attribute information has already been retrieved, the software places that component. If the attribute information has not been retrieved, the software displays an error message telling you that the component cannot be located.