Flanged Connections
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Equipment |
- |
Read-only |
|
2 |
Pipe run |
Non-working |
Full control/ Write |
|
3 |
Base flange associated with the pipe run |
|||
Result: If the equipment is deleted, the software deletes the equipment. The software generates a to Do Record for the connection at the flange. You must have Wrtie access on the flange connection to update the To Do Record. |
||||
Before deletion |
After deletion |
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Equipment |
- |
Read-only |
|
2 |
Pipe run |
Working |
Full control/ Write |
|
3 |
Mating flange associated with the pipe run |
|||
Result: If the equipment is deleted, the software deletes the equipment, including the mating flange and all associated connections with the pipe run. |
||||
Before deletion |
After deletion |
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Equipment |
- |
Read-only |
|
2 |
Pipe run |
Non-working |
Full control/ Write |
|
3 |
Mating flange associated with the pipe run |
|||
Result: If the equipment is deleted, the software deletes the equipment, including all associated connections with the pipe run. The software generates a To Do Record for the mating flange, because it is in non-working state. You must have Write access to the mating flange to update the To Do Record. |
||||
Before deletion |
After deletion |
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Equipment |
- |
Read-only |
|
2 |
Pipe run |
Non-working |
Full control/ Write |
|
3 |
Mating flange associated with the pipe run |
|||
4 |
Component associated with the pipe run |
|||
Result: If the equipment is deleted, the software deletes the equipment. The software generates a To Do Record for the component. You must have Write access on the component to update the To Do Record. |
||||
Before deletion |
After deletion |
Welded Connections
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Equipment |
- |
Read-only |
|
2 |
Pipe run |
Non-working |
Full control/ Write |
|
3 |
Welded connection |
|||
Result: If the equipment is deleted, the software deletes the equipment. The software generates a To Do Record for the weld. You must have Write access on the pipe run to update the To Do Record. |
||||
Before deletion |
After deletion |
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Equipment |
- |
Read-only |
|
2 |
Pipe run |
Working |
Full control/ Write |
|
3 |
Mating flanges associated with the pipe run |
|||
4 |
Component associated with the pipe run |
|||
Result: If the equipment is deleted, the software deletes the equipment, including all associated connections with the pipe run. |
||||
Before deletion |
After deletion |
No. |
Route Object |
Approval Status |
Permission Group Access |
|
---|---|---|---|---|
1 |
Equipment |
- |
Read-only |
|
2 |
Pipe run |
Non-working |
Full control/ Write |
|
3 |
Mating flanges associated with the pipe run |
|||
4 |
Component associated with the pipe run |
|||
Result: If the equipment is deleted, the software deletes the equipment, including all associated connections with the pipe run. The software generates a To Do Record for the mating flange, because it is in non-working state. You must have Write access to the mating flange to update the To Do Record. |
||||
Before deletion |
After deletion |