Route a pipe run at specified distance - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Piping

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Help
Smart 3D Version
13.1
SmartPlant Foundation / SDx Version
10
  1. Click Tools > PinPoint Command.

  2. Select the Relative Tracking option on the PinPoint ribbon.

  3. Select the Rectangular Coordinates option on the PinPoint ribbon.

  4. Click Route Pipe Command on the vertical toolbar.

  5. Select the run starting point.

  6. Define the pipe run properties on the New Pipe Run Dialog, and then click OK.

  7. On the PinPoint ribbon, type the easting, northing, or elevation distance (from the PinPoint target) to route the pipe run.

  8. Click in the view to route the pipe run to the specified point. The software moves the PinPoint target to the new location.

  9. On the PinPoint ribbon, type the easting, northing, or elevation distance to route the pipe run.

  10. Continue defining points as needed.

  11. Select the ending point of the pipe run. Right-click to end a pipe run.

If the piping specification that you selected has service limits defined, you must define at least one temperature value and one pressure value for the pipe run. You do this by selecting Temperature and Pressure from the Category option.