Displays and defines the general properties of the split feature.
Split features inherit some properties from the parent pipe run. If you change the pipe run property, the corresponding split properties also automatically change.
Category
Pipe split properties are divided into different categories: Standard, Insulation and Tracing, and Surface Treatment and Coating. You can select the category to define values by using the Category option.
Standard
Pipeline
Displays the system to which the split feature belongs. You cannot change the system of the split feature.
Pipe Run
Specifies the pipe run to which the split feature belongs.
<Load More Runs>
Loads all the runs that belong to the parent pipeline system. This option is not available after you load all the runs, or if the parent pipeline system has less than 200 runs.
More
Displays the Select Pipe Run Dialog. Select More to select a pipe run that is associated with a different pipeline.
Specification
Specifies the active pipe specification for the split feature. All the pipe specifications that are allowed to be selected as the system parent of the pipe run appear for selection. If appears in the box, the pipe specification is inherited from the pipe run to which the split feature belongs. If the icon does not appear, and you want to use the pipe specification from the pipe run, select Use Run Specification.
Nominal Diameter
Specifies the nominal diameter (NPD) of the split feature. If appears in the box, the NPD for the split feature is inherited from the pipe run to which the split feature belongs. If the icon does not appear, and you want to use the pipe specification from the pipe run, select Use Run NPD. If you have manually selected the part, the NPD of the selected part appears and cannot be changed.
Weld/Takedown Category
Select the category for the split.
Type
Displays the types of split components allowed by the selected Specification, Nominal Diameter, and Weld/Takedown Category options. Split components are listed by short codes. You can change the split type if needed. If you have manually selected the part, this box displays Part selected manually and cannot be changed.
Option
Displays a list of available split features. The software generates this list based on the pipe specification, the NPD, and the short code that you selected in the Type box. If you have manually selected the part, this box displays Part selected manually and cannot be changed.
Base Part Name
Displays the part name for the split feature. The software selects the part name using the pipe specification guidelines. Select the Select Manually option to override the pipe specification, and select the part number from the catalog. If you select a part manually, the Nominal Diameter, Type, and Option properties are disabled.
Correlation Status
Specifies whether the object has been correlated to an object in a P&ID. The list is defined by the EFWCorrelationStatus select list.
Correlation Basis
Specifies whether the object is correlated to a P&ID object. The list is defined by the EFWCorrelationBasis select list.
Correlate Object
Indicates that the object has a correlating object in a P&ID.
No correlation is required
Indicates that the object does not have a correlating object in a P&ID.
Correlation Approval Status
Specifies whether the object is approved with discrepancies in the three-dimensional data compared with design basis data. The list is defined by the EFWCorrelationApprovalStatus sheet in the AllCodelist workbook.
Topology mismatch approved
Indicates that the object topology mismatch can be ignored.
Data and Topology mismatches approved
Indicates that the object data and topology mismatches can be ignored.
None
Indicates that you do not approve a mismatch.
Insulation and Tracing
Insulation Specification
Specifies the insulation specification for the object. If Inherited Properties or Spec displays in the box, the insulation specification for the object is inherited from the pipe run to which the object belongs.
Defines which insulation specifications are available for which systems in System and Specifications. Insulation specifications are defined in the reference data.
Not Insulated
Disables the remaining insulation properties.
User Defined
Indicates that you can specify the remaining insulation properties using custom settings.
More
Displays a dialog so that you can select an insulation specification from the reference data. The software then automatically enters information from that insulation specification.
Insulation Purpose
Specifies the purpose of the insulation. If you selected Not Insulated in the Insulation Specification box, you cannot change the information in the Insulation Purpose box. However, if Insulation Specification is manually defined, you can select the purpose of the insulation in this box. If Insulation Specification is a selected reference data insulation specification, the software reads the purpose from the insulation specification from the reference data and displays it here.
To change the options on the list, edit the Insulation Purpose select list in Catalog.
Insulation Material
Specifies the material of the insulation.
Piping
If you selected Not Insulated in the Insulation Specification box, you cannot change the value in the Insulation Material box. However, if you manually entered the insulation specification, you must provide a corresponding insulation material as per the specification. If you selected an insulation specification from the available list, the software automatically displays the corresponding material as per the specification.
HVAC
If you select Not Insulated, you cannot change the information in Insulation Thickness.
Select More to select an insulation material from the Catalog. To change the options on the list, edit the Insulation Material select list in Catalog. See Select Insulation Material Dialog.
Insulation Thickness
Specifies the thickness of the insulation.
Piping
If you selected Not Insulated in the Insulation Specification box, you cannot change the value in the Insulation Thickness box. However, if you manually entered the insulation specification, you must provide a corresponding insulation thickness value as per the specification. If you selected an insulation specification from the available list, the software automatically displays the corresponding thickness value as per the specification.
HVAC
If you selected Not Insulated in the Insulation Material box, this property is unavailable.
Insulation Temperature
Specifies the temperature. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example) when specifying this value.
Heat Tracing Requirement
Specifies whether the object is heat-traced. To change the options on the list, edit the Heat Tracing Medium select list in Catalog.
Heat Tracing Type
Specifies the type of heat-tracing. To change the options on the list, edit the Heat Tracing Medium select list in Catalog.
Heat Tracing Medium
Specifies the heat-tracing medium to apply to the object. To change the options on the list, edit the Heat Tracing Medium select list in Catalog.
Heat Tracing Medium Temperature
Specifies the temperature of the heat-tracing medium. Include the unit of measurement of temperature (K for Kelvin, F for Fahrenheit, or C for Celsius, for example).
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.
Surface Treatment and Coating
Interior Surface Treatment Requirement
Specifies the interior treatment requirement for the object. To change the options on the list, edit the Interior Surface Treatment select list in Catalog.
Interior Surface Treatment Type
Specifies the interior treatment type for the object. To change the options on the list, edit the Interior Surface Treatment select list in Catalog.
Exterior Surface Treatment Requirement
Specifies the exterior treatment requirement for the object. To change the options on the list, edit the Exterior Surface Treatment select list in Catalog.
Exterior Surface Treatment Type
Specifies the exterior treatment type for the object. To change the options on the list, edit the Exterior Surface Treatment select list in Catalog.
Cleaning Requirement
Specifies the cleaning requirement for the object. To change the options on the list, edit the Cleaning Requirement select list in Catalog.
Steamout Requirement
Specifies the steamout requirement for the object. To change the options on the list, edit the Steamout Requirement select list in Catalog.
Steamout Pressure
Specifies the steamout pressure for the object. Include the pressure unit of measure (psi for pounds per square inch for example).
Steamout Temperature
Specifies the steamout temperature for the object. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example).
Auxiliary Treatment Requirement
Specifies the auxiliary treatment requirement. To change the options on the list, edit the Auxiliary Treatment select list in Catalog.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .
User Driven
Allows you to select a value. Click to switch to Rule Driven .
Auxiliary Treatment Type
Specifies the auxiliary treatment type for the object. To change the options on the list, edit the Auxiliary Treatment select list in Catalog.
Interior Coating Requirement
Specifies the interior coating requirement for the object. To change the options on the list, edit the Coating Type sheet in the AllCodeLists.xls workbook in the reference data.
Interior Coating Type
Specifies the type of interior coating for the object. To change the options on the list, edit the Coating Type sheet in the AllCodeLists.xls workbook in the reference data.
Interior Coating Area
Specifies the area of the interior coating for the object.
Exterior Coating Requirement
Specifies the coating requirement for the object. To change the options on the list, edit the Coating Type select list in Catalog.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .
User Driven
Allows you to select a value. Click to switch to Rule Driven .
Exterior Coating Type
Specifies the type of coating for the object. To change the options on the list, edit the Exterior Coating Type select list in Catalog.
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.
Exterior Coating Area
Specifies the area of the coating for the object.
Coating Color
Specifies the color of the object coating. To change the options on the list, edit the Coating Color select list in Catalog. Smart 3D includes this property in the painting area report.
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.