Adjust the Default Change of Direction rule for sloped piping - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Piping

Language
English
Product
Intergraph Smart 3D
Subproduct
Piping
Search by Category
Help
Smart 3D Version
13.1
SmartPlant Foundation / SDx Version
10

The Catalog must contain appropriate bend angles in the Default Change of Direction rule for Smart 3D to correctly place turn fittings for sloped pipe runs.

  1. Click Task > Catalog.

  2. Navigate to Default Change of Direction Rule.

  3. Adjust the Bend Angle From and Bend Angle To values as necessary so that the bend angles account for the slope variation.

    Default Change of Directions Rules CONCEPT

  4. Bulk load any changed bend angles. See Loading Reference Data into the Catalog in the Smart 3D Reference Data Help.

  5. Click Task > Piping.

  6. Route the sloped pipe.

    Smart 3D calculates the appropriate turn fittings for the sloped pipe run.

  • When routing a sloped pipe, use a slope value that is larger than the Minimum Slope for the pipe run to avoid To-Do-Record (TDR). The software compares design slope and minimum slope of the pipe run. If there is a difference between the values caused by any modification, the software generates a TDR.