Because the Short Code is not a property used to create the unique ID definition, type M at the beginning of the record, and then apply the changes to the existing record. For example, the new requirement dictates that a reducing tee is placed for 4"x2" lines instead of a weldolet.

  1. Open the Pipe Branch Rule sheet.

  2. Locate the record, edit the Short Code value, and then type M at the beginning of the record.

  3. Bulkload the spreadsheet, and review the log file.

  4. Because editing the Short Code impacts the modeled objects, use the Synchronize Model with Catalog Command to mark the out-of-date objects.

  5. Use the Synchronize Workspace with Catalog Command to update the objects.

  6. Verify your changes, and resolve any discrepancies.

Edit Short Code