Open the Piping Specification.xls workbook.
-
Select the FieldFitLength sheet.
-
Select a row after the Start keyword but before the End keyword, and click Insert > Row.
-
In the Weld Type column, enter the weld type code for which to define a field fit length.
-
Specify the NPD range for the field fit length.
-
Specify the constructions requirements.
-
In the Field Fit Length column, enter the field fit length. Be sure to include the units of measure, for example in or mm, when specifying this value.
-
Save the Piping Specification.xls workbook.
Refer to Field Fit Length for more information about the columns in this sheet.