Split Built Up by Built Up - 90º Opposite Connect Points - Intergraph Smart 3D - Help

Intergraph Smart 3D Molded Forms

Language
English
Product
Intergraph Smart 3D
Subproduct
Molded Forms
Search by Category
Help
Smart 3D Version
12 (2018)

DM1 and DM2 were created by splitting the original design member by DM3. DM1 and DM2 use cardinal point 2. DM3 uses cardinal point 8.

  • This configuration is modeled with DM1 and DM2 using cardinal point 2 and DM3 using cardinal point 8. There is not a frame connection between the crossing members before the split. The member axes must intersect for the software to create the split. If there is a gap between the two crossing systems, the software cannot create the logical connections. Structural Detailing requires a connection to detail this case. The lapped property on the structural framing connection is sufficient for this.

  • The orientation of the split is determined by the plane through the intersection point of the two member axes. This plane is normal to the split member axis.

  • Structural Detailing does not create a connection between DM1 and DM2.

  • If you place manual logical connections between the plate systems for DM1 and DM2, then assembly connections and physical connections are created as children of the manual logical connections.