Controls the overflow of the material list to subsequent drawing sheets
-
Same Sheet gives automatic overflow onto a secondary material list plotted alongside the first. This setting creates a wider non-standard drawing size.
-
Continuation Sheet gives a second "dummy" isometric containing the overflow material list but no isometric graphics. With this setting, the isometric is allocated the next drawing (sheet) identifier in the sequence.
For Smart 3D models, we recommend that you set Material List Overflow to Continuation Sheet if you also select Change Management Enabled,
Defines:
Option Switch - 30, Pos 1
I-Configure - MaterialList.MaterialListOverflow