13.0(2016)

Controls the use of user-specified Isometric Reference Dimension control points for determining reference dimension placement locations on the pipeline. You can also specify whether this property is used in conjunction with the Automatic Placement setting.

  • On places user-defined reference dimensions on the pipeline as specified by the Isometric Reference Dimension control point. You can place any number of Isometric Reference Dimension control points.

  • On -- Override Automatic prevents the software from placing an automatic reference dimension regardless of the Automatic Placement setting.

  • Off defers to the Automatic Placement setting.

Defines:

Option Switch - N/A
I-Configure - S3D.Drawing.Dimensions.ColumnReference.UserPlacement

  • You must associate an Isometric Reference Dimension control point with a piping part. The software does not detect this type of control point if it is associated with a pipe feature or pipe run. In these instances, the software writes an error in the log file but still produces the piping isometric drawing, minus the reference dimension.

  • You can place an Isometric Reference Dimension control point anywhere along the centerline of the associated part, including the end points. For more information, see Control Point in the Common Help.