Spool Drawing Name Rule - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Isogen Isometric Drawings

Language
English
Product
Intergraph Smart 3D
Subproduct
Drawings and Reports
Search by Category
Help
Smart 3D Version
13.1
Isogen Version
13.0(2016)

Controls the spool drawing identifier used on spool isometrics.

  • Default produces an identifier that consists of the pipeline name followed by the spool identifier (set by AText -257 to default of SPL) followed by the spool number. If the the spool has been named, only the spool name is used.

    Without spool name:

    With spool name:

  • User produces an identifier that consists of the pipeline name followed by the user-specified spool name.

    If the spool is not named, then the spool drawing identifier is the same as the default.

  • Auto Pipeline Ref produces an identifier that consists of the pipeline name followed by spool number. If the the spool has been named, only the spool name is used.

    Without spool name:

    With spool name:

    spoolidpre5-1named

  • Auto Pipeline Filename produces an identifier that consists of the pipeline filename followed by spool number.If the the spool has been named, only the spool name is used.

    Without spool name:

    With spool name:

    spoolidpre5-1named

Defines:

Option Switch - 39, Pos 4-5
I-Configure - Drawing.Format.SpoolDrawingID