Cut Off - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Isogen Isometric Drawings

Language
English
Product
Intergraph Smart 3D
Subproduct
Drawings and Reports
Search by Category
Help
Smart 3D Version
13.1
Isogen Version
13.0(2016)

Defines the minimum slope treated as a fall. The default value is 5°. The minimum value is 1°.

Type 0 to use a 5° angle cut-off or its equivalent depending upon the type of indication selected by Fall Representation. Alternatively, type a value that defines a cut-off number to suit the type of indication selected by Fall Representation.

  • For fall cut off of 5 Degrees, type 5 or 0.

  • For fall cut off of 1:11 Ratio, type 11.

  • For fall cut off of 9 Percent, type 9.

  • For fall cut off of 5 Grads, type 5.

  • For fall cut off of 1" Per foot, type 1.

  • For fall cut off of 88 mm per meter, type 88.

Defines:

Option Switch - 20
I-Configure - Drawing.Format.FallCutOff

  • Always set Cut Off to 0 when sloping pipeline indication has been suppressed by Fall Representation.

  • Slopes steeper than the cut-off value are shown with a 2D or 3D box or triangle skew indication as appropriate.