Controls the dimensioning of branches based on the number of components. Gasket and bolt entries are counted as components.

Type a value in the range 0-99. Branches that contain a number of components less than or equal to the specified value are not dimensioned. The branch in the example has six components: a weldolet, a weld-neck flange, two gaskets, a valve, and a blind flange. Setting Component Count to 6 or higher results in the branch not being dimensioned.

  • To dimension all branches, type 0.

  • Isogen does not suppress dimensions for any branch that contains pipe or pipe block.

  • Isogen treats fixed length pipe as a component. As such, branch dimensions are suppressed.

  • You cannot use Component Count to suppress dimensions for tapped branches.

  • Component Count can work independently of or in conjunction with Nominal Size, depending upon your requirements.

Defines:

Option Switch - 81, Pos 7-8
I-Configure - Drawing.Dimensions.BranchCPTLimit