Controls the dimensioning of tee and tap branches to allow dimensioning to the edge of pipe.

Click Show Collapse ICP to display a gallery of shapes, and then select the appropriate setting.

  • CentreLine originates dimensions from the centerlines of the main run.

  • TapAndSetOnStartPoint dimensions to the edge of pipe.

  • TapStartPoint defines tap dimensions only.

Defines:

Option Switch - 81, Pos 9
I-Configure - Drawing.Dimensions.TapBranchDimension

For Smart 3D cable tray and HVAC isometric drawings, use this option to allow dimensioning to the edge of cable tray and duct, respectively.