Number of Drawings - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Isogen Isometric Drawings

Language
English
Product
Intergraph Smart 3D
Subproduct
Drawings and Reports
Search by Category
Help
Smart 3D Version
13.1
Isogen Version
13.0(2016)

Specifies the number of drawing sheets required for split control. This property is not available for Smart 3D cable tray isometric drawings or Smart 3D HVAC isometric drawings.

For automatic control of drawing numbers, type 0. To specify the number of drawings, type a value in the range 1-99.

Defines:

Option Switch - 7, Pos 1-2
I-Configure - Drawing.Controls.NoOfDrawing

  • Unless you also select Ignore User Split Points, Isogen ignores the Number of Drawings setting if manually placed pipeline split points are present in the pipeline data file.

  • Number of Drawings dictates how many drawing sheets are extracted for a pipeline. Because this setting applies to all the pipelines in a run, you should use this property only for special cases for single pipe runs.

  • To use Number of Drawings, you must also clear the Automatic Drawing Splitting check box.