Display BOP coordinates at turns - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Isogen Isometric Drawings

Language
English
Product
Intergraph Smart 3D
Subproduct
Drawings and Reports
Search by Category
Help
Smart 3D Version
13.1
Isogen Version
13.0(2016)

In the following isometric, the elevation shown at the elbow is the centerline elevation. You can configure the style file to output bottom-of-pipe (BOP) elevations at turns.

  1. Right-click an Isogen Isometric Drawing by Query component or package in the Management Console or Drawing Console, and then click Edit Options to open Isogen Configuration.

  2. From the Home screen, navigate to Smart 3D.Content.General, and click the Output BOP Coordinates check box.

  3. Click Save to update the isometric style file with the new isometric drawing option settings, and then exit Isogen Configuration.

  4. Update the drawing and review the isometric output using the View Extraction Data Command. The elevation shown is now a BOP elevation.

  5. Review the related PCF. The ELBOW record now includes a BOP-ELEVATION attribute,