Integrating with Intergraph Smart P&ID - Intergraph Smart 3D - Installation & Upgrade - Hexagon

Intergraph Smart 3D Installation

Language
English
Product
Intergraph Smart 3D
Search by Category
Installation & Upgrade
Smart 3D Version
13.1

To take full advantage of the software's Intergraph Smart P&ID integration functionality, we recommend that you install the Piping Specification Remote Access Server and Client setups. The remote access server setup is available as an option in the Smart 3D Installation setup for the workstation computer. The remote access client is an available option with the Intergraph Smart P&ID product and is installed on a computer running Intergraph Smart P&ID.

The Piping Specification utility works with Smart 3D to validate the piping materials class with the temperatures, pressures, and diameters assigned to the pipe run. The utility also searches commodity codes for piping components. The database tables and library files in the 3D product provide source information for the validation and search. For more information about this utility, see the Intergraph Smart P&ID Remote Pipe Specification Access Quick Reference Guide, which is available in the Technical Notes and White Papers section on the Smart Community.

  • Install Intergraph Smart P&ID first if you plan to install Intergraph Smart P&ID and Smart 3D on the same computer.

  • When installing the Piping Specification Remote Access Server component, you must also install the Bulkload Reference Data and the Server Connectivity components as they are required for the Piping Specifications Remote Access Server to work.

  • In order to use Piping Specification Remote Access you must perform additional installation and configuration on the computers running Intergraph Smart P&ID. See the Installing Smart 3D Piping Specification Remote Access Client section in the Intergraph Smart P&ID Installation and Upgrade Guide for more information. Also, see the Piping Specification Utility section in the Intergraph Smart P&ID Utilities Guide for additional configuration information.

  • The server used by the Piping Specification Remote Access Client and the SP3D P&ID Client Tester application is the computer on which the Piping Specification Remote Access Server Windows service has been installed and configured. This server can be different from the database server on which the Site database server and Site schema server reside.

For more specific information about using the Intergraph Smart P&ID integration functionality included with the software, please contact Customer Support.

See Also

Configure the Piping Specification Remote Access Server Service
Register the Site Database for P&ID Access